21
WPS-700-DOM-A Installation Manual
© 2012 Wirepath Surveillance
L/L SYNC
Line Lock Sync is used to reduce picture “roll” when the camera is
connected to an AC power supply and its picture is switched with other
cameras on a monitor.
MONITOR TYPE
Select CRT or LCD based upon the type of monitor being used to
view the camera.
FACTORY RESET
If adjustment to the camera’s settings results in poor picture quality,
it is recommended to restore the camera to factory default settings.
AllcongurationswiththeexceptionoftheCOMMSETTINGScanbe
reset to factory default settings by selecting FACTORY RESET and
pressing the MENU button. This option does not have an "UNDO"
feature, so ensure default settings are desired before selecting this
function.
COMM Set
The communication setting is used to remotely
control the camera’s OSD (On-Screen Display)
from a PTZ controller or DVR through RS-485.
This is helpful for adjusting camera settings
after installation without having to be next
to the camera.
• PROTOCOL: The communication protocol is preset to PELCO-D.
This is the protocol how a PTZ controller or DVR remotely controls
the OSD.
Warning:ConrmthatalldevicesinthesystemusethesameProtocol.
• CAMERA ID
- CAMERA ID: Select a unique
number from 0 to 255
Warning: If multiple cameras
anddevicesarebeingusedin
thesurveillancesystem,conrm
thatnootherdeviceisusingthe
sameID.Iftwoormoredevices
sharethesameIDnumber,thePTZcontrollerorDVR
willnotbeabletocontrolorcongureanyofthedevices.
<COMM SETTING MENU>
PROTOCOL PELCO-D
CAMERA ID 1
BAUDRATE 9600
PREVIOUS
<SET CAMERA ID>
CAMRA ID 000 |------------
DISPLAY ID OFF
ID POSITION
PREVIOUS